FAQ Lists
1 |
How to print the buffer ? |
At the programmer software, click manu,select Buffer ->Save Buffer; Open with notepad, and print. |
|
2 |
Why Superpro/L+ and Z appear the communication error under win2000/XP ? |
In the WIN2000/XP operating system, tacitly approves and the mouthworking pattern is not in original WIN9X/ME EPP or the ECP pattern, as a result of the communication agreement change, the programming is unable with the computer and the mouth grasps the seat of honor,therefore the communication is not successful. In view of this kind ofquestion, some two methods may attempt: 1st, and the mouth LPT working pattern will change EPP or ECP in CMOS; 2nd, one can solve the overwhelming majority computer communicationthrough the plan to make a mistake the question, if the situationstill were unable to solve, only had adopts to old exchanges theservice, changed into the new generation of USB series programming tosolve. |
|
3 |
What is ISP programming? How does it work? |
When selecting devices, you will always find ISP in the brackets behind some ICs. If a device supports online programming, that is, IC has been welded on the PCB, but you have to reprogram without disassembly, then ISP programming is your need. Besides, some devices without corresponding adapters also need ISP. Ours is ISP-HEADER01, containing 10 feet, Connection mode is introduced detailed in software (Note: Not all IC support ISP). | |
4 |
When viewing devices list, I find one IC has two or more adapters to support. How can I choose? |
It often appears in SUPERPRO/3000U. Adapters contain general adapters and special adapters. Special adapters are tailor-made for individual devices, so they only support less IC than general adapters, yet some of these ICs can't be supported by general adapters. If one IC can be supported by two adapters, you should choose according to production and later expansion of other chips. Take HD64F3684GFP-TQFP64 For example, it belongs to RENESAS, and can be supported by two adapters, which are TA043-B006 (a special adapter) and PEP+S616 (a general adapter). Users can choose by themselves. | |
5 |
Why it always takes much time to response when programming large-capacity devices such as NANDFLASH? |
As the unique character characteristics of SUPERPRO/9000U, it loads program automatically whenever operated. If the FLASH’s capacity is small, no significant time differences can be found, but for large capacity, it will take a long waiting time. Solution: as little duplicated modification of BUFFER as possible, once having chosen don't repeat the operation. | |
6 |
Why my Superpro/9000U can't connect the computer? |
First check hardware and drivers. Whether SUPERPRO/9000U is in the on-line mode or offline mode, the standard CF card must be inserted in the programmer. | |
7 |
Why I can't find correct types of EPROM, MCU and PLD by "AUTO DINF DEVICE" function? |
"AUTO FIND DEVICE" function only applies to standard logic circuit of 74/4000 series , as well as user's self-building devices in library. | |
8 |
How can I get the Chinese-language interface? |
All the software for windows has Chinese-language version. Select CHINESE in selection box when installing, otherwise you will get the default version - English version. | |
9 |
After the first installation of the software, Communication error is reported once on line |
All the software of our company is burned in a CD-ROM. A dialog for selecting programmers will arise when auto playing. If wrong software corresponding to programmer models is chosen or parallel Port programmer in Win2000/NT/XP, please refer to this page for solution. Otherwise, contact us. | |
10 |
My programmer is the former, and does not support WINDOWS2000/NT/XP, but I have to use these operating systems, What can I do? |
Method 1: Install multi-guidance on computer, multiple operating systems coexist. Method 2: Replace your programmer with a new model. Refer to "replacement". |
|
11 |
My operating system is WINDOWS2000/NT/XP. What type of programmer can be used in such operating system? |
New generations of programmers such as: SUPERPRO/680, SUPERPRO/580, SUPERPRO/280, SUPERPRO/8000, SUPERPRO/2000 +, SUPERPRO/2000, SUPERPRO/1000 are all supported. | |
12 |
Chips with DIP package are programmed normally, but with other package like PLCC or QFP there are problems, why? |
At this time you should check whether the adapter's model is correct, and whether the adapter is produced originally. It is often found some persons use dead sockets on printed circuit board to imitate testing sockets (use few-yuan product to imitate hundred-yuan). We suggest when buying adapters, you should reach an agreement with sellers, that is, if the adapters are not produced by the manufacturers or can not be used, sellers should pay for several times of the purchase price.(Some even use "XELTEK YYYY-MM-DD" on their imitated printed circuit boards, which violates national law seriously). | |
13 |
How many times of the adapter can used ? |
In general, the expectancy of an adapter depends on the expectancy of the socket. Our sockets are all imported from overseas, so the quality is guaranteed and not like some poor sockets, and can achieve manufacturers' technical indicators with normal operation. Improper operation may damage sockets, including: using welding chips to program, improper operation artificially and so on. | |
14 |
According to the advertisement, SUPERPRO has SRAM test function, but why can't be found in TEST? |
TEST doesn't have SRAM test function. Select manufacture and model like EPROM, and execute TEST in RUN. | |
15 |
How to burn two files into one chip? |
You can load the two files respectively, make sure "Buffer clear when data loaded" in the data buffer unchecked. | |
16 |
How to burn a 16-bit file into two 8-bit EPROMs respectively by even/odd bytes? |
When loading files, set FILE MODE as EVEN , thus the 0th , 2nd , 4th...bytes are loaded into the buffer and program even chips. Then set FILE MODE as ODD, thus the 1st, 3rd, 5th... bytes are loaded, and program odd chips. If you do it like this, in order to improve efficiency, save into two files separately after loading, and load corresponding files next time. the same operation for 32-bit files. | |
17 |
Why it can't work on board but verify successfully while burning 87C196XX? |
Why it can't work on board but verify successfully while burning 87C196XX The starting address of 87C196XX program is 2000H, while a general document's OFFSET address is also 2000H. SUPERPRO's BUFFER 0 corresponds to 2000H in 87C196XX, so make sure FILE OFFSET is 2000H when loading files. There are many similar situations, such as MOTOROLA microcontroller, its offset is very large, even larger than buffer, so you will get a warning message when loading files OFFSET. At this time you should set FILE OFFSET correctly. Software will also display the detected OFFSET value automatically. |
|
18 |
Why it can't work on board but verify successfully while burning PIC16CXXX and PHILIPS 89CXXX |
Many devices have configuration bits or bytes, which is used to selecting oscillator types, or setting WDT. It can work only after correct configure. Click button "CONFIGURATION" in Menu "RUN" and configure in the configuration dialog box, then return to "RUN" and execute PROGRAM", it will burn configure word or registers automatically after programming | |
19 |
Why can't find the driver the new USB series programming? |
This is because each system difference creates, solution: Single-clicks the right key in ' My Computer ', choice ' Attribute ', in ' Hardware ' In the option card clicks on 'the equipment management ', found the driver in ' the equipmentmanagement ' which cannot distinguish. generally is the yellow sighsthe number demonstration, selects this equipment to single-click theright key choice ' Update the drivers', chooses in assigns theposition installment actuation, the actuation way generally in toinstall in the table of contents ' bin ' in the table of contents tofind then installs completes; If or can not complete please contact with our company to explain! |
|
20 |
In the NANDFLASH read-write programming process prompts Good blocks not enough. |
This is because had to burn the data which recorded to surpass the chip good block size, therefore the establishment component disposition character (Dev.Config) also should unify the chip theactual situation, if inspected in the chip to have 16 bad blocks, that actual good block (ALL Blocks) should correspondingly subtract 0x10. Sometimes also can have such situation in the read-write femaleinstant, when inspects bad block how many discovered has very many badblocks. This is because in the female piece bad block flag bit isshifted to other places. Tacitly approves the bad block flag bit waswritten the effective data. | |
21 |
In the NANDFLASH regulation prompts Config Error, does not permit the operation |
Has such situation is because the component disposition character(Dev.Config) the center parameter establishes is improper. The correct establishment should be such: UBA start block should be issmaller than All Blocks, Size of UBA blocks should be smaller than orbe equal to All Blocks subtracts UBA start block. Boot start blockshould be is smaller than All Blocks, Size of Boot blocks is smallerthan or was equal to All Block subtracts UBA start block. If under the Reserved pattern, UBA start block should be issmaller than RBA start block, Size of UBA blocks also should be issmaller than RBA start block to subtract UBA start block, RBA startblock should be bigger than UBA start block to add Size of UBA blocks,and is smaller than All Blocks, Size of RBA blocks should be smallerthan All Blocks to subtract RBA start block. |
|